섹션 5:
Global Actions and Legislation and Regulation.
a) Montreal Protocol.
1) Control release of ozone depleting substances.
2) Ban importing and exporting.
3) Reduce production , eventually elimination.
4) Agreement to subsequent meetings and cooperation fostering accelerated phase out
ozone depleting substances.
5) Agreement to Kigali Agreement to phase down HFC's.
몬트리올회담:
미주환경청에서 적용하기 시작한 환경 보호과정중에 중요한 역할을 하게 되는 환경회담으로
* 환경을 해치는 냉매대기 배출 금지
* 수입과 수출금지. (* 모든 냉매공장시설을 해외로 이전. )
* 생산량을 줄이거나 생산량 감소.
* 오존파괴 냉매 사용을 줄여나가면서 없애기로 하는 회담에 동의.
* 최근에는 케갈리 회담이후 HFC계통의 냉매도 사용금지하기로 동의.
(* 개정된 조례 중심으로 시험에 자주 출제되는 사항. )
b) Purpose of U.S. Clean Air Act of 1990.
▪ Reduce Production.
▪ Promote Conservation.
* of Ozone-depleting substances to lowest achievable levels.
공기정화법이란 ;
* 생산량을 줄이며
* 에너지 절제를 위하며
* 오존파괴 냉매를 최소화 하기로 하며,
EPA regulations of Refrigerant Management :
1) Service Practices.
a) Intentional venting/Recovery , extended to substitute refrigerants such as
HFC's.
b) Refrigerant transfer ( to system receiver ), or, recovered to/by a certified
recovery recycle machines.
EPA냉매관리 조례사항으로는
* 냉매배기 배출 관리를 신대체냉매로 늘리기로 하면서,
* 냉매회수 방법중 펌프다운//수액기 사용, 회수방법이나 재활용방법에 대한 인증사항.
2) Technician certification.
a) Technician defined. Any person performing maintenance, service or repair of
A/C or refrigerant equipment that could reasonably be expected to release CFC,
HCFC, HFCs and substitute refrigerants into the atmosphere.
Including disposal (* except motor vehicle A/C ) that could release refrigerant.
기술자의 자격증 관계;
혼합냉매 및 대체냉매 포함하여 수리, 관리, 서비스 하려 할때 및 폐기처분하려 할때 대기에 냉매를 누출할수 있는 사람/기술자를 의미하며 미환경청에서 요구하는 냉매취급자격증 소지를 요구하며,
3) Activity included in definitions of technician.
a) Attaching and detaching hoses and gauges.
b) Adding or removing refrigerant.
c) Any activity that violate the integrity of the refrigerant circuit when charged
with refrigerant.
기술자의 정의로;
* 게이지나 호스를 띄였다 붙였다 하는 행동,
* 냉매 충전 혹은 회수하는 행동,
* 냉매가 들어 있는 회로에 해를 주려고 하는 행동을 하려고 하는 기술자를 이야기 하며
4) Activities excluded in definition of technicians.
a) Activities that so not violate the integrity of the refrigerant circuit such as
painting, rewiring, replacing insulation and fasteners.
b) Maintenance, service, repair or disposal of appliances that has refrigerant
recovered and evacuated per EPA regulations.
c) Service and disposing of motor vehicle air conditioning systems (* #609
required )
d) The purchase of " small cans " containing less than 20 lbs of refrigerant, in
which 609 Certification required.
e) While only certified technicians may purchase container of 20 lbs and over of
refrigerant or pre-charged split systems and component pre-charged with
refrigerant, assembled //manufactured units such as household refrigerators,
window and packaged units are exempt.
f) Refrigerant changing hands between manufacturers and wholesalers are
exempt. And contractors are allowed to have " clerks or runners " pick-up
and deliver refrigerant.
기타 냉매의 정상적인 가동과는 관계없이
* 페인팅, 전선배선, 절연체 설치, 혹은 볼트조이기,
* 자동차 폐기//#609 항목에 속하는 행위//무자격.
* 20파운드 미만 냉매탱크 구입불가.
* 주로 20파운드 이상의 냉매 구입은 자격증 소유자에 한하며 기타 이미 제조과정에 냉매가 들어 있는 공조기 구매 혹은 조립//가정용 냉장고, 창문용 에어컨 구입설치는 예외 조항으로 하며,
* 냉매구입시에 도매상과 소매상의 거래 및 심부름 할때의 거래과정은 허가 하기로 합니다.
*** 아세요?
***번역하여 올려드리는 한글번역분은 국제저작권 보호에 적용되기도 하기에 함부로 허가없이 복사 배포할수 없음을 분명히 알려드리며 협조를 부탁드립니다.***
시험에 자주 출제되는 사항으로 되풀이되는 문제이기에 돌아오는 세미나/시험 기회를 주어질 환경에 대비하여 열공하시기 바랍니다.
All Copyright Protected and Reserved.
보조기사 올림.