현장의소리

[스크랩] compressor overheat

heatingkim 2011. 11. 23. 08:19

Overheat is has been a major cause of compressor fallures.

Temperatures in the compressor head and cylinder become so hot that the oil thins and loses its ability to lubricate. This may cause rings,pistons.and cylinders to wear resuliting in blow by leaking valves and metal debris in the oil lt can also cause the stator to ground due to a spot burn.

 

Cylinder temperatures exceeding 300F(148C) will begin the breakdown of oil and at 350F(176C) oil will be vaporized.

Tomeasure cylinder temperature, place your temperature gauge no more than six inches out on the discharge line from the compressor. For most applications the temperature should be below 225F(107C). This factors in a 50-75 degree temperature drop from the cylinder to the measured point.

 

To correct for overheat:

 

1. Correct abnormally low load conditions.

2. Correct high discharge and low suction pressure conditions.

3. Insulate suction lines, clean dirty condensers.

4. Provide proper compressor cooling.

5. Check low pressure control settings.

 

Pressure controls can help to identify or remedy system problems.

 

 

출처 : 워싱톤 한인 냉동기술인 협회
글쓴이 : 메릴랜드 원글보기
메모 :